Parameters
List of parameters
1-142
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the standstill (stall) torque for rotating synchronous motors (p0300 = 2xx).
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is automatically preset for motors from the motor list (p0301).
This parameter is not used for induction motors (p0300 = 1xx).
This parameter value is not evaluated from a control-related perspective.
Description: Sets the standstill (stall) force for linear synchronous motors (p0300 = 4xx).
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is automatically preset for motors from the motor list (p0301).
This parameter value is not evaluated from a control-related perspective.
Description: Induction motors:
Sets the rated motor magnetizing current.
For p0320 = 0.000 the magnetizing current is internally calculated and displayed in r0331.
Synchronous motors:
Sets the rated motor short-circuit current.
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is automatically preset for motors from the motor list (p0301).
VECTOR: If, for induction motors, the magnetizing current p0320 is changed outside the commissioning phase
(p0010 > 0), then the magnetizing inductance p0360 is changed so that the EMF r0337 remains constant.
p0319[0...n] Motor stall torque / Mot M_standstill
SERVO Can be changed: C2(3) Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 7_4 Unit selection: p0100
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [Nm] 100000.00 [Nm] 0.00 [Nm]
p0319[0...n] Motor stall force / Mot F_standstill
SERVO (Lin) Can be changed: C2(3) Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 8_4 Unit selection: p0100
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [N] 100000.00 [N] 0.00 [N]
p0320[0...n] Motor rated magnetization current/short-circuit current / Mot I_mag_rated
SERVO, VECTOR Can be changed: C2(3), U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 5722
P-Group: Motor Units group: - Unit selection: -
Not for motor type: REL, FEM Expert list: 1
Min Max Factory setting
0.000 [Arms] 5000.000 [Arms] 0.000 [Arms]