Parameters
List of parameters
1-824
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Index: [0] = Alarm threshold
[1] = Fault threshold
Dependency: Refer to: r4104
Warning: Fault F35207 only causes the drive to be shut down if there is at least one BICO interconnection between the drive
and TM31.
Note: The temperature sensor is connected at terminals X522.7(+) and X522.8(-).
A value > 250 °C deactivates the alarm or fault.
Description: Displays the status for the temperature evaluation of terminal module 31 (TM31).
This displays as to whether the temperature actual value has exceeded the fault/alarm threshold.
Dependency: Refer to: p4102
Description: Displays the actual temperature value of the temperature evaluation of terminal module 31 (TM31).
Dependency: For sensor type PTC (p4100 = 1), the following applies:
- below the nominal response temperature, r4105 = -50°C.
- above the nominal response temperature, r4105 = 250 °C.
For sensor type KTY84-130 (p4100 = 2), the following applies:
- the displayed value corresponds to the temperature actual value.
Refer to: p4100
Note: The temperature sensor is connected at terminals X522.7(+) and X522.8(-).
For an invalid temperature actual value, (e.g. a short-circuit at the sensor input), r4105 = -300 °C is displayed.
Description: Displays the unfiltered speed setpoint N_SETPT in revolutions per minute for diagnostic purposes.
In contrast to p1155, this value is updated in each DRIVE-CLiQ basic clock cycle and displayed with sign.
Dependency: Refer to: r4155
r4104.0...1 BO: TM31 temperature evaluation, status / TM31 temp status
TM31 Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: 1840, 9576
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Temperature alarm threshold exceeded Yes No -
01 Temperature fault threshold exceeded Yes No -
r4105 CO: TM31 temperature evaluation, actual value / TM31 temp actValue
TM31 Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 1840, 9576
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r4154 TM41 diagnostics speed setpoint non-filtered / n_set non-filt
TM41 Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]