Description: Number of parameters in the inhibit list p0571 that should be withdrawn from the automatic motor and closed-loop
control parameter calculation (refer to p0340, p0578), starting from index 0.
Note: Defines the number of entries in p0571 that should be taken into account. This means that a value of 0 de-activates
the complete list.
Description: The inhibit list contains parameters that should be withdrawn from the automatic motor and closed-loop control
parameter calculation (p0340, p0578).
Values: 0: No parameter
640: Current limit
1082: Maximum speed
1460: Speed controller P gain
1462: Speed controller integral action time
1470: Speed controller P gain, sensorless
1472: Speed controller integral action time sensorless
1520: Torque limit upper/motoring
1521: Torque limit lower/regenerative
1530: Power limit motoring
1531: Power limit regenerating
Note: p0570 defines the number of entries (starting at index 0) for which the inhibit should apply. p0572 can be used to
define for which drive data sets the inhibit list should apply.
If a motor data set is entered into a parameter number, then this is not overwritten as soon as only one drive data
set refers to the motor data set (p0186).
Description: Enable ID as to whether the parameters of the inhibit list p0571 should be overwritten when calculating the motor
and closed-loop control parameters for the particular drive data set (index = DDS).
Values: 0: No
1: Yes
Note: 0: The automatic calculation (p0340, p0578) also overwrites the parameters of list p0571.
1: The automatic calculation (p0340, p0578) does not overwrite the parameters of list p0571.
p0570 Inhibit list: Number of effective values / Inhib list: Qty
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 50 0
p0571[0...49] Inhibit list, motor/closed-loop control parameter calculation / Inhib list calc
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1531 0
p0572[0...n] Activate inhibit list / Act inhib list
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0