EasyManua.ls Logo

Siemens SINAMICS S Series - p0301[0...n] Motor code number selection; Mot code No. sel

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-132
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice: The list for motor codes /encoder codes can be found in the following literature:
SINAMICS S List Manual
Note: With p0300 = 10000, for a motor with DRIVE-CLiQ, the motor parameters are automatically downloaded, with
p0300 = 10001, the motor parameters of a second data set (if available).
If a motor type has not been selected (p0300 = 0), then the drive commissioning routine cannot be exited.
A motor type with a value above p0300 >= 100 describes motors for which a motor parameter list exists.
Motor types with a value below p0300 < 100 correspond to the selection of an unlisted motor. When appropriately
selected, this means that the motor parameters are pre-assigned the settings for an unlisted motor.
This also applies for parameters for a motor with DRIVE-CLiQ. In this case p0300 can only be set to p0300 = 10000
or 10001 (read motor parameters) or to the corresponding non-Siemens motor (first digit of the motor code number)
in order to be able to cancel the write protection.
Description: The parameter is used to select a motor from a motor parameter list.
When changing the code number (with the exception to the value 0), all of the motor parameters are pre-assigned
from the internally available parameter lists.
Dependency: Only code numbers for motor types can be selected that correspond to the motor type selected in p0300. For 1PH2,
1PH4, 1PH7, 1PM4, 1PM6, 1FT6 motors, code numbers are also possible, whose fourth decimal position is greater
by a value of 1 or 2 than the matching motor type in p0300. For 1FE1 motors, the third decimal position can be
higher by a value of 1.
Refer to: p0300
Notice: The list for motor codes /encoder codes can be found in the following literature:
SINAMICS S List Manual
Note: The motor code number can only be changed if the matching list motor was first selected in p0300.
For a motor with DRIVE-CLiQ, p0301 cannot be changed. In this case, p0301 is automatically written to the code
number of the motor parameter read-in (r0302) if p0300 is set to 10000.
When selecting a list motor (p0300 >= 100), drive commissioning can only be exited if a code number is selected.
If, for direct drives, the motor code number (p0301) is changed, this does not automatically result in the angular
commutation offset being determined (p0431).
Description: The parameter is used to select a motor from a motor parameter list.
When changing the code number (with the exception to the value 0), all of the motor parameters are pre-assigned
from the internally available parameter lists.
Dependency: Only code numbers for motor types can be selected that correspond to the motor type selected in p0300.
Refer to: p0300
Notice: The list for motor codes /encoder codes can be found in the following literature:
SINAMICS S List Manual
Note: The motor code number can only be changed if the matching list motor was first selected in p0300.
When selecting a list motor (p0300 >= 100), drive commissioning can only be exited if a code number is selected.
p0301[0...n] Motor code number selection / Mot code No. sel
SERVO Can be changed: C2(1, 3), U Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: FEM Expert list: 1
Min Max Factory setting
0 65535 0
p0301[0...n] Motor code number selection / Mot code No. sel
SERVO (Lin) Can be changed: C2(1, 3), U Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: FEM Expert list: 1
Min Max Factory setting
0 65535 0

Table of Contents