List of parameters
Parameters
1-223
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the measuring time for a rising edge at the digital input for the "central measuring probe evaluation" func-
tion.
The measuring time is specified as 16-bit value with a resolution of 0.25 µs.
r0686[0]: Measuring time, rising edge measuring probe 1
r0686[1]: Measuring time, rising edge measuring probe 2
r0686[2]: Measuring time, rising edge measuring probe 3
r0686[3]: Measuring time, rising edge measuring probe 4
r0686[4]: Measuring time, rising edge measuring probe 5
r0686[5]: Measuring time, rising edge measuring probe 6
Description: Displays the measuring time for a falling edge at the digital input for the "central measuring probe evaluation" func-
tion.
The measuring time is specified as 16-bit value with a resolution of 0.25 µs.
r0687[0]: Measuring time, falling edge measuring probe 1
r0687[1]: Measuring time, falling edge measuring probe 2
r0687[2]: Measuring time, falling edge measuring probe 3
r0687[3]: Measuring time, falling edge measuring probe 4
r0687[4]: Measuring time, falling edge measuring probe 5
r0687[5]: Measuring time, falling edge measuring probe 6
Bit field: Bit Signal name 1 signal 0 signal FP
00 Falling edge, measuring probe 1 Yes No -
01 Falling edge, measuring probe 2 Yes No -
02 Falling edge, measuring probe 3 Yes No -
03 Falling edge, measuring probe 4 Yes No -
04 Falling edge, measuring probe 5 Yes No -
05 Falling edge, measuring probe 6 Yes No -
08 Rising edge, measuring probe 1 Yes No -
09 Rising edge, measuring probe 2 Yes No -
10 Rising edge, measuring probe 3 Yes No -
11 Rising edge, measuring probe 4 Yes No -
12 Rising edge, measuring probe 5 Yes No -
13 Rising edge, measuring probe 6 Yes No -
r0686[0...5] CO: Central measuring probe, measuring time rising edge / CenMeas t_meas 0/1
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0687[0...5] CO: Central measuring probe, measuring time falling edge / CenMeas t_meas 1/0
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -