List of parameters
Parameters
1-195
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
5: DI/DO 14 (X132.10)
6: DI/DO 15 (X132.11)
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p0489, p0490, p0728
Notice: To the terminal designation:
The first designation is valid for CU320, the second for CU310.
To select the values:
For CU310, CX32, NX10 and NX15, only DI/DO 9, 10, 11 can be selected as fast inputs (refer to the Equipment
Manual).
Note: DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
Refer to the encoder interface for PROFIdrive.
If parameterization is rejected, check whether the terminal is already being used in p0580, p0680, p2517 or p2518.
Description: Sets the input terminal to connect probe 2.
Values: 0: No meas probe
1: DI/DO 9 (X122.8/X121.8)
2: DI/DO 10 (X122.10/X121.10)
3: DI/DO 11 (X122.11/X121.11)
4: DI/DO 13 (X132.8)
5: DI/DO 14 (X132.10)
6: DI/DO 15 (X132.11)
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p0488, p0490, p0728
Notice: To the terminal designation:
The first designation is valid for CU320, the second for CU310.
To select the values:
For CU310, CX32, NX10 and NX15, only DI/DO 9, 10, 11 can be selected as fast inputs (refer to the Equipment
Manual).
Note: DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
Refer to the encoder interface for PROFIdrive.
If parameterization is rejected, check whether the terminal is already being used in p0580, p0680, p2517 or p2518.
Description: Setting to invert the digital input signals to connect a measuring probe or an equivalent zero mark.
p0489[0...2] Measuring probe 2 input terminal / Meas probe 2 inp
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: 4740
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 6 0
p0490 Invert measuring probe or equivalent zero mark / Meas. probe invert
CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 4740
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin