Siemens SINAMICS S Series - p2185[0...n] Load monitoring torque threshold 1, upper; M_thresh 1 upper; p2185[0...n] Load monitoring force threshold 1, upper; M_thresh 1 upper; p2186[0...n] Load monitoring torque threshold 1, lower; M_thresh 1 lower; p2186[0...n] Load monitoring force threshold 1, lower; M_thresh 1 lower

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-598
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency: The following applies: p2185 > p2186
Refer to: p2182, p2186
Refer to: A07926
Note: The upper envelope curve is defined by p2185, p2187 and p2189.
Description: Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency: The following applies: p2185 > p2186
Refer to: p2182, p2186
Refer to: A07926
Note: The upper envelope curve is defined by p2185, p2187 and p2189.
Description: Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency: The following applies: p2186 < p2185
Refer to: p2182, p2185
Refer to: A07926
Note: The lower envelope curve is defined by p2186, p2188 and p2190.
Description: Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency: The following applies: p2186 < p2185
Refer to: p2182, p2185
Refer to: A07926
p2185[0...n] Load monitoring torque threshold 1, upper / M_thresh 1 upper
SERVO (Extended
msg), VECTOR
(Extended msg)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 8013
P-Group: Messages Units group: 7_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [Nm] 20000000.00 [Nm] 10000000.00 [Nm]
p2185[0...n] Load monitoring force threshold 1, upper / M_thresh 1 upper
SERVO (Extended
msg, Lin)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 8013
P-Group: Messages Units group: 8_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [N] 100000.00 [N] 100000.00 [N]
p2186[0...n] Load monitoring torque threshold 1, lower / M_thresh 1 lower
SERVO (Extended
msg), VECTOR
(Extended msg)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 8013
P-Group: Messages Units group: 7_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [Nm] 20000000.00 [Nm] 0.00 [Nm]
p2186[0...n] Load monitoring force threshold 1, lower / M_thresh 1 lower
SERVO (Extended
msg, Lin)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 8013
P-Group: Messages Units group: 8_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [N] 100000.00 [N] 0.00 [N]