Parameters
List of parameters
1-868
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Selects the fifth signal to be traced.
For trace with a physical address (p4784), the data type of the signal to be traced (recorded) is set here.
The parameter can only be written to if the number of trace channels (p4702) is eight.
Index: [0] = Trace 0
[1] = Trace 1
Description: Selects the sixth signal to be traced.
For trace with a physical address (p4785), the data type of the signal to be traced (recorded) is set here.
The parameter can only be written to if the number of trace channels (p4702) is eight.
Index: [0] = Trace 0
[1] = Trace 1
Description: Selects the seventh signal to be traced.
For trace with a physical address (p4786), the data type of the signal to be traced (recorded) is set here.
The parameter can only be written to if the number of trace channels (p4702) is eight.
Index: [0] = Trace 0
[1] = Trace 1
Description: Selects the eighth signal to be traced.
For trace with a physical address (p4787), the data type of the signal to be traced (recorded) is set here.
The parameter can only be written to if the number of trace channels (p4702) is eight.
Index: [0] = Trace 0
[1] = Trace 1
p4734[0...1] Trace record signal 4 / Trace record sig 4
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - 0
p4735[0...1] Trace record signal 5 / Trace record sig 5
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - 0
p4736[0...1] Trace record signal 6 / Trace record sig 6
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - 0
p4737[0...1] Trace record signal 7 / Trace record sig 7
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - 0