EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-78 2493 - IF2 send telegram, free interconnection via BICO (p0922 = 999)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
PROFIdrive
2-1186
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-78 2493 – IF2 send telegram, free interconnection via BICO (p0922 = 999)
- 2493 -
Function diagram
87654321
fp_2493_01_eng.vsd
DO: A_INF, B_INF, S_INF
SINAMICS S
29.06.07 V02.05.01
PROFIdrive - IF2 send telegram, free interconnection via BICO (p0922 = 999)
<1> In order to maintain the PROFIdrive profile, send word 1 must be used as status word 1 (E_ZSW1).
<2> Using the binector/connector converters at [2472], bits of 4 send words can be interconnected with any binectors.
<3> The following representation applies for words: 4000 hex = 100 %.
The reference variables p880x apply for the ongoing interconnection (100 % -> p880x).
The following applies for temperature values: 100 °C -> 100 % = 4000 hex; 0 °C -> 0 %.
Refer to [1020.7]
PROFIdrive Abtastzeit
<3>
<1>
PZD send word 6
PZD send word 7
PZD send word 8
(0)
p8851[5]
(0)
p8851[6]
(0)
p8851[7]
PROFIBUS
PROFINET
Drive object n
Header
Drive object 1
Drive object 2
.
.
.
.
.
.
Drive object m
Trailer
IF2 Diag send word 1...7
r8853[0...6]
...
PZD send word 1
PZD send word 2
PZD send word 3
PZD send word 4
PZD send word 5
<2>
(0)
p8851[1]
(0)
p8851[2]
(0)
p8851[3]
(0)
p8851[4]
(0)
p8851[0]
PROFIdrive send telegram
Reference quantities for further interconnection
p880x

Table of Contents

Related product manuals