EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-168 6030 - Speed setpoint, droop

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vector control
Function Diagrams
2-1287
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-168 6030 – Speed setpoint, droop
- 6030 -
Function diagram
87654321
fp_6030_01_eng.vsd
DO: VECTOR
SINAMICS S
18.04.07 V02.05.00
Vector control - Speed setpoint, droop
Droop input source
0...3
p1488 (0)
3
2
1
0
r0079
M_set total
M_set before M_suppl
r1508
0
Droop scaling
0.000...0.500
p1489 [D] (0.050)
10
0
+
-
r1170
n_ctr setp sum
n_limit pos effective
r1084
n_limit negative effective
r1087
r0079
M_set total
a at M_ctrl scal
0.0...400.0 [%]
p1499 [D] (100.0)
n_set limited
r1407.11
Droop enabled
r1407.10
Enable droop
r1406.11
n_set limited
r1407.11
n_set_filter 1 T
0.00...5000.00 [ms]
p1416 [D] (0.00)
0
1
M_ctrl active
r1407.2
Pre-control speed
r1490
Droop n_reduction
0
<1>
<1>
<1> = Only for vector control without encoder.
[6060.8]
[3050.8]
[3050.8]
[3080.8]
[6060.5]
r1482
n-ctrl I_output
[6060.8]
[6730.1]
[6490.7]
1 = Sensorless vector control, speed pre-control active
from speed control configuration
p1400.15
Droop input
[6060.3]
r0060
n_set before filt.
<2> Refer to speed actual value smoothing [6040.2]
[2520.7]
p1492
[2522.3]
[2522.3]
Mot moment of inertia ratio
1.000...10000.000
p0342 [M] (1.000)
Mot M_inertia
0.00000...100000.00000 [kgm²]
p0341 [M] (0.00000)
<3> Scaling: p1489 = 0.100 - for a rated motor torque of r0333 - results in a speed setpoint reduction of 0.1 x p0311.
<3>
N
M
n
N
[2522.3]
[6031.1]
r0062
n_set after filter
150 ms
1 0
[6040.8]
[2701.1]
[2704.1]
[6799.1]
Refer to [1020.7]
p0115[y] (Motor Modules)
Mom of inert scal
(100)
p1497[C]