Siemens SINAMICS S Series - p3080 Motor identification - flux controller P gain; MotId flux ctrl Kp; p3081 Motor identification - flux controller integral action time; MotId flux ctrl Tn; p3082 Motor identification - current controller P gain; MotId I_ctrl Kp; p3083 Motor identification - current controller integral action time; MotId I_ctrl Tn

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-692
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Proportional gain of the flux controller set from the motor identification.
Note: For synchronous motors, this parameters has no effect.
Description: Integral action time of the flux controller set from the motor identification.
Note: For synchronous motors, this parameters has no effect..
Description: Proportional gain of the current controller set from the motor identification.
Description: Integral action time of the current controller set from the motor identification.
Description: Sets the mode for the time stamp
p3100 = 0: Time stamp, operating hours
p3100 = 1: Time stamp, UTC format
p3080 Motor identification - flux controller P gain / MotId flux ctrl Kp
SERVO Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
0.0 [A/Vs] 999999.0 [A/Vs] 0.0 [A/Vs]
p3081 Motor identification - flux controller integral action time / MotId flux ctrl Tn
SERVO Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p3082 Motor identification - current controller P gain / MotId I_ctrl Kp
SERVO Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: 18_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.000 [V/A] 100000.000 [V/A] 0.000 [V/A]
p3083 Motor identification - current controller integral action time / MotId I_ctrl Tn
SERVO Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [ms] 1000.00 [ms] 0.00 [ms]
p3100 RTC time stamp mode / RTC t_stamp mode
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0