List of parameters
Parameters
1-81
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the transformation angle.
Dependency: Refer to: r0093, p0431, r1778
Note: The transformation angle corresponds to the electrical commutation angle.
If no pole position identification is carried out (p1982), and the encoder is adjusted, the following applies:
The encoder supplies the value and indicates the electrical angle of the flux position (d axis).
Description: Executes an automatic device configuration.
In so doing, p0099, p0107 and p0108 are appropriately set.
Values: 0: No selection
1: Drive object type SERVO
2: Drive object type VECTOR
3: SINAMICS GM (DFEMV & VECTORMV)
4: SINAMICS SM (AFEMV & VECTORMV)
5: SINAMICS GL (VECTORGL)
12: Drive object type VECTOR parallel circuit
13: Drive object type VECTORMV - GM parallel circuit
14: Drive object type VECTORMV - SM parallel circuit
Dependency: Refer to: r0098, p0099
Refer to: A01330
Note: For p0097 = 0, p0099 is automatically set to the factor setting.
The setting p0097 = 1 is not possible for chassis-type power units as well as for SINAMICS G or SINAMICS GM.
The setting p0097 = 12 is not possible for booksize power units.
Description: Displays the automatically detected actual device topology in coded form.
Index: [0] = DRIVE-CLiQ socket X100
[1] = DRIVE-CLiQ socket X101
[2] = DRIVE-CLiQ socket X102
[3] = DRIVE-CLiQ socket X103
[4] = DRIVE-CLiQ socket X104
[5] = DRIVE-CLiQ socket X105
Dependency: Refer to: p0097, p0099
r0094 CO: Transformation angle / Transformat_angle
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1580, 4710,
4715, 6714, 6730
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [°] - [°] - [°]
p0097 Select drive object type / Select DO type
CU_CX32, CU_S Can be changed: C1(1) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 14 0
r0098[0...5] Actual device topology / Device_act topo
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -