Siemens SINAMICS S Series - r0380[0...n] Motor damping inductance, d axis; Mot L_damping_d; r0381[0...n] Motor damping inductance, q axis; Mot L_damping_q; r0382[0...n] Motor magnetizing inductance transformed; Lh d axis saturated; Mot L_m tr;Lhd sat; r0383[0...n] Motor magnetizing inductance q axis, saturated; Mot L_magn q sat

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-165
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the damping inductance of the separately-excited synchronous motor in the rotor direction (d-axis).
Description: Displays the damping inductance of a separately-excited synchronous motor quadrature to the rotor direction (q
axis).
Description: Displays the magnetizing inductance of the motor.
For separately-excited synchronous motors: Displays the saturated magnetizing inductance in the rotor direction (d-
axis).
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the saturated magnetizing inductance of a separately-excited synchronous motor quadrature to the rotor
direction (q axis).
Description: Displays the rotor time constant.
For separately-excited synchronous motors: Displays the damping time constant in the rotor direction (d-axis).
r0380[0...n] Motor damping inductance, d axis / Mot L_damping_d
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0381[0...n] Motor damping inductance, q axis / Mot L_damping_q
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0382[0...n] Motor magnetizing inductance transformed / Lh d axis saturated / Mot L_m tr/Lhd sat
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0383[0...n] Motor magnetizing inductance q axis, saturated / Mot L_magn q sat
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0384[0...n] Motor rotor time constant / damping time constant d axis / Mot T_rotor/T_Dd
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 6722
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]