List of parameters
Parameters
1-165
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the damping inductance of the separately-excited synchronous motor in the rotor direction (d-axis).
Description: Displays the damping inductance of a separately-excited synchronous motor quadrature to the rotor direction (q
axis).
Description: Displays the magnetizing inductance of the motor.
For separately-excited synchronous motors: Displays the saturated magnetizing inductance in the rotor direction (d-
axis).
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the saturated magnetizing inductance of a separately-excited synchronous motor quadrature to the rotor
direction (q axis).
Description: Displays the rotor time constant.
For separately-excited synchronous motors: Displays the damping time constant in the rotor direction (d-axis).
r0380[0...n] Motor damping inductance, d axis / Mot L_damping_d
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0381[0...n] Motor damping inductance, q axis / Mot L_damping_q
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0382[0...n] Motor magnetizing inductance transformed / Lh d axis saturated / Mot L_m tr/Lhd sat
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0383[0...n] Motor magnetizing inductance q axis, saturated / Mot L_magn q sat
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 15_1 Unit selection: p0349
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0384[0...n] Motor rotor time constant / damping time constant d axis / Mot T_rotor/T_Dd
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 6722
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]