List of parameters
Parameters
1-749
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the v coordinate of the 4th value pair of the friction characteristic.
Dependency: Refer to: p3833, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 5th value pair of the friction characteristic.
Dependency: Refer to: p3834, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the v coordinate of the 5th value pair of the friction characteristic.
Dependency: Refer to: p3834, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 6th value pair of the friction characteristic.
Dependency: Refer to: p3835, p3845
p3823[0...n] Friction characteristic, value v3 / Friction v3
SERVO (Lin) Can be changed: T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 4_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [m/min] 21000.00 [m/min] 12.00 [m/min]
p3824[0...n] Friction characteristic, value n4 / Friction n4
SERVO, VECTOR
(n/M)
Can be changed: T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 3_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [RPM] 210000.00 [RPM] 150.00 [RPM]
p3824[0...n] Friction characteristic, value v4 / Friction v4
SERVO (Lin) Can be changed: T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 4_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [m/min] 21000.00 [m/min] 15.00 [m/min]
p3825[0...n] Friction characteristic, value n5 / Friction n5
SERVO, VECTOR
(n/M)
Can be changed: T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 3_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [RPM] 210000.00 [RPM] 300.00 [RPM]