Description: Displays the edge status for digital input 16 ... 23 of terminal module 15 (TM15).
Assignment of the digital inputs to the bits:
DI 16: r4313.1 ... 0
DI 17: r4313.3 ... 2
DI 18: r4313.5 ... 4
DI 19: r4313.7 ... 6
DI 20: r4313.9 ... 8
DI 21: r4313.11 ... 10
DI 22: r4313.13 ... 12
DI 23: r4313.15 ... 14
Possible edge states:
Bit x, y = 0, 0 --> no edge detection
Bit x, y = 0, 1 --> 1st edge detected
Bit x, y = 1, 0 --> 2nd edge detected
Bit x, y = 1, 1 --> both edges detected
Note: DI: Digital input
Description: Displays the time when detecting the 1st and 2nd edge for digital input 0 of terminal module 17 (TM17).
The two times are specified as 16 bit values with a resolution of 0.25 µs.
Note: DI: Digital input
Description: Displays the time when detecting the 1st and 2nd edge for digital input 0 of terminal module 15 (TM15).
The two times are specified as 8 bit values with a resolution of 64 µs.
Note: DI: Digital input
r4313 TM15 edge status digital input 16 ... 23 / TM15 EdgSt DI16-23
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4350 TM17 edge times digital input 0 / TM17 edge_t DI 0
TM17 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4350 TM15 edge times digital input 0 / TM15 edge_t DI 0
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -