Parameters
List of parameters
1-438
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the lower force limit of all force limits.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529, p1532
Description: Displays the maximum limit for the torque-generating current component.
Description: Displays the minimum limit for the torque-generating current component.
Description: Displays the actually effective upper torque limit.
Note: The effective upper torque limit is reduced with respect to the upper torque limit p1520, if the current limit p0640 is
reduced or the rated magnetizing current of the induction motor p0320 is increased.
For vector drives (refer to p0107), this is possibly the case for rotating measurements (refer to p1960).
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
r1535 CO: Force limit lower, total / F_max lower total
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1610, 5620,
5630, 5640
P-Group: Closed-loop control Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [N] - [N] - [N]
r1536 Current limit maximum torque-generating current / Isq_max
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 6640, 6710
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1537 Current limit minimum torque-generating current / Isq_min
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 6640, 6710
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1538 CO: Upper effective torque limit / M_max upper eff
SERVO, VECTOR
(n/M)
Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 1590, 1610,
1750, 5610, 5650, 5714, 6040,
6060, 6640, 8012
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]