Siemens SINAMICS S Series - p2177[0...n] Motor locked delay time; Mot lock t_del; p2178[0...n] Motor stalled delay time; Mot stall t_del; p2181[0...n] Load monitoring response; Load monit resp

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-595
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the delay time for the message "Motor locked" (BO: r2198.6).
If "Motor locked" is identified within this time, then ZSW2.6 is set and an appropriate fault is output.
Dependency: Refer to: p0500, p2175, r2198
Description: Sets the delay time for the message "Motor stalled" (BO: r2198.7).
If "Motor stalled" is identified within this time, then ZSW2.7 is set and an appropriate fault is output.
Dependency: Refer to: r2198
Description: Sets the response when evaluating the load monitoring.
Values: 0: Load monitoring disabled
1: A07920 for torque/speed too low
2: A07921 for torque/speed too high
3: A07922 for torque/speed out of tolerance
4: F07923 for torque/speed too low
5: F07924 for torque/speed too high
6: F07925 for torque/speed out of tolerance
Dependency: Refer to: p2182, p2183, p2184, p2185, p2186, p2187, p2188, p2189, p2190, r2198
Refer to: A07920, A07921, A07922, F07923, F07924, F07925
Note: The response to the faults F07923 ... F07925 can be set.
p2177[0...n] Motor locked delay time / Mot lock t_del
SERVO, VECTOR Can be changed: U, T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 8012
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.000 [s] 65.000 [s] 1.000 [s]
p2178[0...n] Motor stalled delay time / Mot stall t_del
VECTOR Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 8012
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.000 [s] 10.000 [s] 0.010 [s]
p2181[0...n] Load monitoring response / Load monit resp
SERVO (Extended
msg), VECTOR
(Extended msg)
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: DDS, p0180 Func. diagram: 8013
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 6 0