List of parameters
Parameters
1-177
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the number of measuring steps per revolution for a rotary absolute encoder. The resolution refers to the abso-
lute position.
Caution: This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Description: Sets the distance between two zero marks for a linear encoder. This information is used for zero mark monitoring.
Caution: This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note: For distance-coded zero marks, this means the basic distance.
Description: Sets the distance in pulses between two zero marks for a rotary encoder. This information is used for zero mark
monitoring.
Caution: This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note: For distance-coded zero marks, this means the basic distance.
Description: Sets the baud rate for an SSI encoder.
Caution: This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note: SSI: Synchronous Serial Interface
p0423[0...n] Absolute encoder rotary single-turn resolution / Enc abs singleturn
SERVO, VECTOR Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: EDS, p0140 Func. diagram: 4704
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1073741823 8192
p0424[0...n] Encoder, linear zero mark distance / Enc lin ZM_dist
SERVO, VECTOR Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [mm] 65535 [mm] 20 [mm]
p0425[0...n] Encoder, rotary zero mark distance / Enc rot dist ZM
SERVO, VECTOR Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: EDS, p0140 Func. diagram: 4704, 8570
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 16777215 2048
p0427[0...n] Encoder SSI baud rate / Enc SSI baud rate
SERVO, VECTOR Can be changed: C2(4) Calculated: - Access level: 3
Data type: Floating Point Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [kHz] 65535 [kHz] 100 [kHz]