EasyManua.ls Logo

Siemens SINAMICS S Series - r2671 CO: EPOS actual position setpoint; s_set act; r2672 CO: EPOS actual velocity setpoint; v_set act; r2673 CO: EPOS actual acceleration override; a_over act; r2674 CO: EPOS actual deceleration override; �a_over act

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-673
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the position setpoint presently being processed.
Note: A position of zero is displayed for non position-related tasks (e.g. ENDLESS_POS, ENDLESS_NEG).
Description: Displays the velocity setpoint presently being processed.
Description: Displays the acceleration override presently being processed.
Note: An override of 100% is effective in the "jogging" and "search for reference" operating modes.
Description: Displays the deceleration override presently being processed.
Note: An override of 100% is effective in the "jogging" and "search for reference" operating modes.
r2671 CO: EPOS actual position setpoint / s_set act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3610, 3616,
3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [LU] - [LU] - [LU]
r2672 CO: EPOS actual velocity setpoint / v_set act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3610, 3612,
3616, 3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [1000 LU/min] - [1000 LU/min] - [1000 LU/min]
r2673 CO: EPOS actual acceleration override / a_over act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 3610, 3612,
3616, 3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r2674 CO: EPOS actual deceleration override / -a_over act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 3610, 3612,
3616, 3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]

Table of Contents