List of parameters
Parameters
1-673
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the position setpoint presently being processed.
Note: A position of zero is displayed for non position-related tasks (e.g. ENDLESS_POS, ENDLESS_NEG).
Description: Displays the velocity setpoint presently being processed.
Description: Displays the acceleration override presently being processed.
Note: An override of 100% is effective in the "jogging" and "search for reference" operating modes.
Description: Displays the deceleration override presently being processed.
Note: An override of 100% is effective in the "jogging" and "search for reference" operating modes.
r2671 CO: EPOS actual position setpoint / s_set act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3610, 3616,
3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [LU] - [LU] - [LU]
r2672 CO: EPOS actual velocity setpoint / v_set act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3610, 3612,
3616, 3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [1000 LU/min] - [1000 LU/min] - [1000 LU/min]
r2673 CO: EPOS actual acceleration override / a_over act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 3610, 3612,
3616, 3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r2674 CO: EPOS actual deceleration override / -a_over act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 3610, 3612,
3616, 3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1