List of parameters
Parameters
1-135
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
- torques/forces: p0312, p0319
- power ratings: p0307
- masses/moments of inertia: p0341, p0344
All other parameters take into account the replacement/equivalent motor (e.g. r0331, r0370, r0373, r0374).
Dependency: Refer to: r0331, r0370, r0373, r0374, r0376, r0377, r0382
Caution: The motors to be connected-up in parallel, must be of the same type.
The mounting regulations when connecting motors in parallel must be carefully maintained!
The number of motors set must correspond to the number of motors that are actually connected in parallel.
After changing p0306, it is imperative that the control parameters are adapted (e.g. using automatic calculation with
p0340 = 1).
Notice: If p0306 is changed during quick commissioning (p0010 = 1), then the maximum current p0640 is appropriately pre-
assigned. This is not the case when commissioning the motor (p0010 = 3).
Note: Only possible for SERVO!
Description: Sets the rated motor power (rating plate).
Dependency: IECdrives (p0100 = 0): Units kW
NEMA drives (p0100 = 1): Units hp
Refer to: p0100
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is automatically preset for motors from the motor list (p0301).
Description: Sets the rated motor power (rating plate).
Dependency: IECdrives (p0100 = 0): Units kW
NEMA drives (p0100 = 1): Units hp
Refer to: p0100
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is automatically preset for motors from the motor list (p0301).
For generators, a negative rated power should be entered.
p0307[0...n] Rated motor power / Mot P_rated
SERVO Can be changed: C2(1, 3) Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 14_6 Unit selection: p0100
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [kW] 100000.00 [kW] 0.00 [kW]
p0307[0...n] Rated motor power / Mot P_rated
VECTOR Can be changed: C2(1, 3) Calculated: - Access level: 1
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 14_6 Unit selection: p0100
Not for motor type: - Expert list: 1
Min Max Factory setting
-100000.00 [kW] 100000.00 [kW] 0.00 [kW]