A02047 Function generator: Time slice clock cycle invalid
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: The time slice cycle selected does not match any of the existing time slices.
See also: p4830 (Function generator time slice cycle)
Remedy: Input an existing time slice cycle. The existing time slices can be read out via p7901.
Note:
The alarm is reset as follows:
- remove the cause of this alarm.
- restart the function generator.
See also: r7901 (Time slice cycle times)
A02050 Trace: Start not possible
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: The trace has already been started.
See also: p4700 (Trace control)
Remedy: Stop the trace and, if necessary, start again.
A02055 Trace: Recording time too short
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: The trace duration is too short.
The minimum is twice the value of the trace clock cycle.
See also: p4721 (Trace recording time)
Remedy: Check the selected recording time and, if necessary, adjust.
A02056 Trace: Recording cycle too short
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: The selected recording cycle is shorter than the selected basis clock cycle 0 (p0110[0]).
See also: p4720 (Trace recording cycle)
Remedy: Increase the value for the trace cycle.
A02057 Trace: Time slice clock cycle invalid
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: The time slice cycle selected does not match any of the existing time slices.
See also: p4723 (Time slice cycle for trace)
Remedy: Input an existing time slice cycle. The existing time slices can be read out via p7901.
See also: r7901 (Time slice cycle times)
A02058 Trace: Time slice clock cycle for endless trace not valid
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: The selected time slice clock cycle cannot be used for the endless trace
See also: p4723 (Time slice cycle for trace)