Siemens SINAMICS S Series - p9570 SI motion acceptance test mode (Control Unit); SI Mtn Acc_mode; r9571 SI motion acceptance test status (Control Unit); SI Mtn acc_status; p9580 SI motion pulse cancelation delay time after bus failure (CU); SI Mtn t to IL; r9590[0...2] SI motion version safety motion monitoring (Control Unit); SI Mtn version

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-1015
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: A change only becomes effective after a POWER ON.
SLS: Safely-Limited Speed / SG: Safely reduced speed
Description: Setting to select and de-select the acceptance test mode.
Values: 0: [00 hex] De-select the acceptance test mode
172: [AC hex] Select the acceptance test mode
Dependency: Refer to: p9558, r9571
Refer to: C01799
Description: Displays the status of the acceptance test mode.
Values: 0: [00 hex] Acc_mode inactive
12: [0C hex] Acc_mode not possible due to POWER ON fault
13: [0D hex] Acc_mode not possible due to incorrect ID in p9570
15: [0F hex] Acc_mode not possible due to expired Acc_timer
172: [AC hex] Acc_mode active
Dependency: Refer to: p9558, p9570
Refer to: C01799
Description: Sets the delay time after which the pulses are safely canceled after a bus failure.
Dependency: Refer to: p9561, p9563
Notice: The parameter is being prepared and is presently ineffective.
Note: A change only becomes effective after a POWER ON.
Description: Displays the Safety Integrated version for the safety motion monitoring functions on the Control Unit.
p9570 SI motion acceptance test mode (Control Unit) / SI Mtn Acc_mode
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex 00AC hex 0000 hex
r9571 SI motion acceptance test status (Control Unit) / SI Mtn acc_status
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex 00AC hex -
p9580 SI motion pulse cancelation delay time after bus failure (CU) / SI Mtn t to IL
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 800.00 [ms] 0.00 [ms]
r9590[0...2] SI motion version safety motion monitoring (Control Unit) / SI Mtn version
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -