Parameters
List of parameters
1-984
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: A change only becomes effective after a POWER ON.
Description: Sets the shutdown velocity for pulse cancelation.
Below this velocity "standstill" is assumed and for STOP B / SS1, the pulses are canceled (by changing to STOP A).
Dependency: Refer to: p9356, p9560
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: A change only becomes effective after a POWER ON.
SS1: Safe Stop 1
Description: Sets the shutdown speed for the pulse cancelation.
Below this speed "standstill" is assumed and for STOP B / SS1, the pulses are canceled (by changing to STOP A).
Dependency: Refer to: p9356, p9560
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: A change only becomes effective after a POWER ON.
SS1: Safe Stop 1
Description: Sets the stop response for the function "safely reduced speed" (SLS).
These settings apply to the individual limit values for SLS.
Values: 0: STOP A
1: STOP B
2: STOP C
3: STOP D
4: STOP E
10: STOP A with delayed pulse cancelation when the bus fails
11: STOP B with delayed pulse cancelation when the bus fails
12: STOP C with delayed pulse cancelation when the bus fails
13: STOP D with delayed pulse cancelation when the bus fails
14: STOP E with delayed pulse cancelation when the bus fails
Index: [0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLP4
p9360 SI motion pulse cancelation shutdown velocity (Motor Module) / SI Mtn IL v_shutMM
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [mm/min] 6000.00 [mm/min] 0.00 [mm/min]
p9360 SI motion pulse cancelation shutdown speed (Motor Module) / SI Mtn IL n_shutMM
SERVO (Safety rot),
VECTOR (Safety rot)
Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [RPM] 6000.00 [RPM] 0.00 [RPM]
p9363[0...3] SI motion SLS stop response (Motor Module) / SI Mtn SLS Stop MM
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 14 2