Parameters
List of parameters
1-62
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
72: MotID: Moment of inertia measurement, step 3
73: MotID: Moment of inertia measurement end
80: MotID: Magnetizing inductance measurement, step 1
81: MotID: Magnetizing inductance measurement, step 2
82: MotID: Magnetizing inductance measurement, step 3
83: MotID: Magnetizing inductance measurement evaluation
84: MotID: Main inductance measurement end
90: MotID: Saturation characteristic. step 1
91: MotID: Saturation characteristic. step 2
92: MotID: Saturation characteristic. step 3
93: MotID: Saturation characteristic evaluation 1
94: MotID: Saturation characteristic evaluation 2
95: MotID: Saturation characteristic end
96: MotID: Converter model, step 1
97: MotID: Converter model, step 2
98: MotID: Converter model, step 3
99: MotID: Converter model, step 4
100: PolID: Motion-based, step 1
101: PolID: Motion-based, step 2
102: PolID: Motion-based, step 3
103: PolID: Motion-based, step 4
104: PolID: Motion-based, step 5
Description: Displays the actual status for the motor data identification (standstill measurement) and the speed/velocity control-
ler optimization (rotating measurement).
Values: 0: No measurement
115: Measurement q leakage inductance (part 2)
120: Speed controller optimization, (vibration test)
140: Calculate speed controller setting
150: Measurement, moment of inertia
170: Measurement, magnetizing current and saturation characteristic
190: Speed encoder test
195: Measurement q leakage inductance (part 1)
200: Rotating measurement selected
210: Pole position identification selected
220: identification, leakage inductance
230: Identification, rotor time constant
240: Identification, stator inductance
270: Identification, stator resistance
290: Identification, valve lockout time
300: Standstill measurement selected
Description: Displays the effective Motor Data Set (MDS) and the effective Encoder Data Sets (EDS).
Index: [0] = Motor Data Set MDS effective
[1] = Encoder1 Encoder Data Set EDS effective
r0047 Motor data ident. routine and speed controller optimization / MotID and n_opt
VECTOR Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 300 -
r0049[0...3] Motor data set/encoder data set effective / MDS/EDS effective
SERVO, VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: 8565
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -