Parameters
List of parameters
1-564
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: IF1: Interface 1
Description: Binector output for bit-serial interconnection of PZD3 received from the PROFIBUS master.
Note: IF1: Interface 1
Description: Binector output for bit-serial interconnection of PZD4 (normally control word 2) received from the PROFIBUS mas-
ter.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Bit 0 On Off -
01 Bit 1 On Off -
02 Bit 2 On Off -
03 Bit 3 On Off -
04 Bit 4 On Off -
05 Bit 5 On Off -
06 Bit 6 On Off -
07 Bit 7 On Off -
08 Bit 8 On Off -
09 Bit 9 On Off -
10 Bit 10 On Off -
11 Bit 11 On Off -
12 Bit 12 On Off -
13 Bit 13 On Off -
14 Bit 14 On Off -
15 Bit 15 On Off -
r2092.0...15 BO: IF1 PROFIdrive PZD3 receive bit-serial / IF1PZD3recvbitw
SERVO, TM41, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2460
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Bit 0 On Off -
01 Bit 1 On Off -
02 Bit 2 On Off -
03 Bit 3 On Off -
04 Bit 4 On Off -
05 Bit 5 On Off -
06 Bit 6 On Off -
07 Bit 7 On Off -
08 Bit 8 On Off -
09 Bit 9 On Off -
10 Bit 10 On Off -
11 Bit 11 On Off -
12 Bit 12 On Off -
13 Bit 13 On Off -
14 Bit 14 On Off -
15 Bit 15 On Off -
r2093.0...15 BO: IF1 PROFIdrive PZD4 receive bit-serial / IF1PZD4recvbitw
SERVO, TM41, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2460
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -