Siemens SINAMICS S Series - p2599 CO: EPOS reference point coordinate value; Ref_pt coord val; p2600 EPOS search for reference, reference point offset; Ref_pt offset; p2601 EPOS flying referencing, inner window; Inner window; p2602 EPOS flying referencing, outer window; Outer window

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-652
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the position value for the reference point coordinate.
This value is set as the actual axis position after referencing or adjustment.
Dependency: Refer to: p2507, p2525, p2595, p2596, p2597, p2598
Description: Sets the reference point offset for search for reference.
Dependency: Refer to: p2598
Description: Sets the inner window for flying referencing.
Value = 0:
The evaluation of the inner window is de-activated.
Dependency: Refer to: p2597, p2602, r2684
Notice: The inner window must be set so that it is smaller than the outer window.
Note: If the difference between the reference point coordinate and detected actual position is less than the inner window,
then no correction is executed for a referenced axis.
If the difference between the reference point coordinate and detected actual position is greater than the inner win-
dow and less than the outer window (p2602), then a correction is executed for a referenced axis.
Description: Sets the outer window for flying referencing.
Value = 0:
The evaluation of the outer window is de-activated.
Dependency: Refer to: p2597, r2684
Refer to: A07489
p2599 CO: EPOS reference point coordinate value / Ref_pt coord val
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3612
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-2147482648 [LU] 2147482647 [LU] 0 [LU]
p2600 EPOS search for reference, reference point offset / Ref_pt offset
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3612
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-2147482648 [LU] 2147482647 [LU] 0 [LU]
p2601 EPOS flying referencing, inner window / Inner window
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3614
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [LU] 2147482647 [LU] 0 [LU]
p2602 EPOS flying referencing, outer window / Outer window
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3614
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [LU] 2147482647 [LU] 0 [LU]