Parameters
List of parameters
1-790
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: Inversion using p4048 has been taken into account.
The setting of the DI/DO as either input or output is of no significance (p4028).
DI/DO: Bidirectional Digital Input/Output
Description: Setting to invert the signals at the digital outputs of the Terminal Board 30 (TB30).
Note: DO: Digital Output
Description: Setting to invert the signals at the digital outputs of terminal module 31 (TM31).
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI/DO 0 (X520.2) High Low -
01 DI/DO 1 (X520.3) High Low -
02 DI/DO 2 (X520.4) High Low -
03 DI/DO 3 (X520.5) High Low -
04 DI/DO 4 (X520.6) High Low -
05 DI/DO 5 (X520.7) High Low -
06 DI/DO 6 (X520.8) High Low -
07 DI/DO 7 (X520.9) High Low -
08 DI/DO 8 (X521.2) High Low -
09 DI/DO 9 (X521.3) High Low -
10 DI/DO 10 (X521.4) High Low -
11 DI/DO 11 (X521.5) High Low -
12 DI/DO 12 (X521.6) High Low -
13 DI/DO 13 (X521.7) High Low -
14 DI/DO 14 (X521.8) High Low -
15 DI/DO 15 (X521.9) High Low -
16 DI/DO 16 (X522.2) High Low -
17 DI/DO 17 (X522.3) High Low -
18 DI/DO 18 (X522.4) High Low -
19 DI/DO 19 (X522.5) High Low -
20 DI/DO 20 (X522.6) High Low -
21 DI/DO 21 (X522.7) High Low -
22 DI/DO 22 (X522.8) High Low -
23 DI/DO 23 (X522.9) High Low -
p4048 TB30 invert digital outputs / TB30 DO invert
TB30 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 9102
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DO 0 (X481.5) Inverted Not inverted -
01 DO 1 (X481.6) Inverted Not inverted -
02 DO 2 (X481.7) Inverted Not inverted -
03 DO 3 (X481.8) Inverted Not inverted -
p4048 TM31 invert digital outputs / TM31 DO invert
TM31 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 9556, 9560,
9562
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin