EasyManua.ls Logo

Siemens SINAMICS S Series - r0025[0...3] CO: Input voltage smoothed; V_inp smooth; r0025 CO: Output voltage smoothed; V_outp smooth; r0026 CO: DC link voltage smoothed; Vdc smooth

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-47
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the smoothed actual value of the input voltage.
Index: [0] = Voltage at the input terminals of the power unit
[1] = Voltage at the VSM and at the input terminals of the line filter
[2] = Voltage of the voltage source from the line supply model
[3] = Smoothed voltage of the voltage source from line supply model
Dependency: Refer to: r0072
Note: Smoothing time constant = 300 ms
The signals are not suitable as process quantity and may only be used as display quantities.
The input voltages are available smoothed (r0025) and unsmoothed (r0072).
r0025[0]: Pulsed voltage at the line supply input terminals of the power unit. The value is calculated from the modu-
lation depth r0074 and is therefore only correct in the closed-loop controlled mode and when the pulses are
enabled.
r0025[1]: Absolute voltage at the input terminals of the line filter or the connection point of a VSM. The value is cal-
culated from the VSM measured values r3661 and r3662 and is therefore equal to 0 if a VSM is not connected.
r0025[2]: Estimated value for the voltage of the voltage source that is calculated in the voltage model of the line
supply PLL.
r0025[3]: Smoothed display value of the filtered source voltage from r0072[3].
Description: Displays the smoothed output voltage of the power unit.
Dependency: Refer to: r0072
Note: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The output voltage is available smoothed (r0025) and unsmoothed (r0072).
Description: Displays the smoothed actual value of the DC link voltage.
Dependency: Refer to: r0070
Notice: This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case, the
unsmoothed value should be used.
Note: A_INF, B_INF, S_INF: smoothing time constant = 300 ms
r0025[0...3] CO: Input voltage smoothed / V_inp smooth
A_INF, S_INF Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 8850, 8950
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r0025 CO: Output voltage smoothed / V_outp smooth
SERVO, VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 1690, 5730,
6799
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r0026 CO: DC link voltage smoothed / Vdc smooth
A_INF, B_INF,
S_INF
Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 5730, 6799,
8750, 8850, 8950
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]