EasyManua.ls Logo

Siemens SINAMICS S Series - r0157 Terminal Module EPROM data version; TM EPROM version; r0158[0...n] Voltage Sensing Module firmware version; VSM FW version; r0158 DRIVE-CLiQ Hub, firmware version; Hub FW version; r0158 Terminal Module Firmware Version; TM FW version

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-106
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the version of the EPROM data of the Terminal Module.
Dependency: Refer to: r0127, r0147
Description: Displays the firmware version of the Voltage Sensing Module (VSM).
Dependency: Refer to: r0018, r0128, r0197, r0198
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the firmware version of the DRIVE-CLiQ Hub Module Cabinet (DMC).
Description: Displays the firmware version of the Terminal Module.
Dependency: Refer to: r0018, r0128, r0148, r0197, r0198
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
r0157 Terminal Module EPROM data version / TM EPROM version
TM15, TM15DI_DO,
TM17, TM31, TM41,
TM54F_MA,
TM54F_SL
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0158[0...n] Voltage Sensing Module firmware version / VSM FW version
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: p0150 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0158 DRIVE-CLiQ Hub, firmware version / Hub FW version
DMC20 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0158 Terminal Module Firmware Version / TM FW version
TM15, TM15DI_DO,
TM17, TM31, TM41,
TM54F_MA,
TM54F_SL
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -