List of parameters
Parameters
1-445
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for the scaling of the lower torque limiting to limit the speed controller output without taking
into account the current and power limits.
Description: Sets the signal source for the scaling of the lower force limiting to limit the velocity controller output without taking
into account the current and power limits.
Description: Sets the signal source for the motoring and negative regenerative power limit.
Dependency: Refer to: p1530, p1531
Note: The resulting power limit when motoring is the minimum from p1530 and the signal that is read-in, the resulting
regenerative power limit is the maximum from p1531 and the negative signal that is read-in.
Description: Sets the scaling of the signal source for the motoring and negative regenerative power limit.
0 signifies no power limiting.
Description: Sets the signal source for supplementary torque 3.
p1554[0...n] CI: Torque limit lower scaling without offset / M_max low offsScal
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6060
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1554[0...n] CI: Force limit lower scaling without offset / F_max low offsScal
SERVO (Lin) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6060
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1555[0...n] CI: Power limit / P_max
VECTOR (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6640
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1556[0...n] Power limit scaling / P_max_scale
VECTOR (n/M) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6640
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 340.28235E36 0.00
p1569[0...n] CI: Supplementary torque 3 / M_suppl 3
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 7010
P-Group: Functions Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 3841[0]