Siemens SINAMICS S Series - p1554[0...n] CI: Torque limit lower scaling without offset; M_max low offsScal; p1554[0...n] CI: Force limit lower scaling without offset; F_max low offsScal; p1555[0...n] CI: Power limit; P_max; p1556[0...n] Power limit scaling; P_max_scale

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-445
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for the scaling of the lower torque limiting to limit the speed controller output without taking
into account the current and power limits.
Description: Sets the signal source for the scaling of the lower force limiting to limit the velocity controller output without taking
into account the current and power limits.
Description: Sets the signal source for the motoring and negative regenerative power limit.
Dependency: Refer to: p1530, p1531
Note: The resulting power limit when motoring is the minimum from p1530 and the signal that is read-in, the resulting
regenerative power limit is the maximum from p1531 and the negative signal that is read-in.
Description: Sets the scaling of the signal source for the motoring and negative regenerative power limit.
0 signifies no power limiting.
Description: Sets the signal source for supplementary torque 3.
p1554[0...n] CI: Torque limit lower scaling without offset / M_max low offsScal
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6060
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1554[0...n] CI: Force limit lower scaling without offset / F_max low offsScal
SERVO (Lin) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6060
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1555[0...n] CI: Power limit / P_max
VECTOR (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6640
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1556[0...n] Power limit scaling / P_max_scale
VECTOR (n/M) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6640
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 340.28235E36 0.00
p1569[0...n] CI: Supplementary torque 3 / M_suppl 3
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 7010
P-Group: Functions Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 3841[0]