EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-83 2522 - Status word speed controller

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Internal control/status words
2-1192
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-83 2522 – Status word speed controller
- 2522 -
Function diagram
87654321
fp_2522_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
26.07.07 V02.05.00
Internal control/status words - Status word, speed controller
1
2
3
4
5
6
7
8
9
10
11
0
Bit No.
12
13
14
15
Vector
-
Servo
-
From torque limiting [5610.4]
From the torque setpoint [6060.4][6060.7]
From the setpoint, n-ctrl [5030.8]
<1> From the speed controller [5210.3]
From the speed setpoint, droop [6030.4][6030.5]
From torque limiting [5610.4]
From the torque setpoint [6060.7]
From torque limiting [5610.4]
From the torque setpoint [6060.7]
Sensorless operation
&
[2520.7]
-
-
-
-
r1407
ZSW n_ctrl
r1407.8
r1407.9
r1407.11
r1407.1
1 = Torque control
r1406.12
r1407.7
From the changeover, closed-loop control types [5060.5]
<1> From the speed controller [5210.8]
From the speed controller [5040.7][6040.7]
<1> From the speed controller [5210.8]
From the speed controller [5040.7][6040.7]
1 = V/f control active
Status word, speed controller
1 = Sensorless operation active
1 = Closed-loop torque control active
1 = Closed-loop speed control active
1 = Speed setpoint from DSC
1 = Speed controller, I component held
1 = Speed controller, I component set
1 = Torque limit reached
1 = Torque limiting, upper, active
1 = Torque limiting, lower, active
1 = Droop enabled
1 = Speed setpoint limited
1 = Ramp-function generator set
1 = Sensorless operation due to a fault
Reserved
Reserved
-
r1407.10
r1407.11
r1407.5
r1407.6
r1407.2
<1> Only for servo control without encoder.
From the control unit [2610.4]
From the speed setpoint, droop [6030.3]
r1407.3
r1407.12
-
r1407.4
To the speed actual value and pole position
sensing, motor encoder (encoder 1)
[4710.4][4715.4]
To speed setpoint, droop [6030.5]
To torque setpoint [6060.3]
Ramp-function generator tracking [3080.1]
“Traveling blocks“ mode [3616.1]
Speed controller [5040.7][5042.5][6040.4]
Motor locked/stalled [8012.5]
<2>
r1407.13
<2> Only for SERVO.
<2>
1000.00 µs
r1407.0
p0115[1] (Motor Modules)
p1190 > 0 (interconnected)
p1191 > 0 (interconnected)
PcCtrl active
Mot-ID
AUS1
1
AUS3
Halt2
&
Bewegungsbasierte
PolID
To Speed setpoint filter [5020.1]
To Reference model [5030.3]

Table of Contents