Parameters
List of parameters
1-606
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the value for fixed value 3 of the technology controller.
Dependency: Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description: Sets the value for fixed value 4 of the technology controller.
Dependency: Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description: Sets the value for fixed value 5 of the technology controller.
Dependency: Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description: Sets the value for fixed value 6 of the technology controller.
Dependency: Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
p2203[0...n] CO: Technology controller, fixed value 3 / Tec_ctrl fix val 3
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7950
P-Group: Technology Units group: 9_1 Unit selection: p0595
Not for motor type: - Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 30.00 [%]
p2204[0...n] CO: Technology controller, fixed value 4 / Tec_ctrl fix val 4
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7950
P-Group: Technology Units group: 9_1 Unit selection: p0595
Not for motor type: - Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 40.00 [%]
p2205[0...n] CO: Technology controller, fixed value 5 / Tec_ctrl fix val 5
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7950
P-Group: Technology Units group: 9_1 Unit selection: p0595
Not for motor type: - Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 50.00 [%]
p2206[0...n] CO: Technology controller, fixed value 6 / Tec_ctrl fix val 6
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7950
P-Group: Technology Units group: 9_1 Unit selection: p0595
Not for motor type: - Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 60.00 [%]