Loading...
CX32 input/output terminals
Function Diagrams
2-1145
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-39 2230 – Digital inputs/outputs, bidirectional (DI/DO 8 ... DI/DO 9)
- 2230 -
Function diagram
87654321
fp_2230_51_eng.vsd
DO: CU_CX32
SINAMICS
19.05.06 V02.05.00
CX32 input/output terminals - Digital inputs/outputs, bidirectional (DI/DO 8 ... DI/DO 9)
p0795.8 (0)
X122.9 M
Simulation
p0796.8
p0748.8 (0)
DI
DO
p0795.9 (0)
Simulation
p0796.9
p0748.9 (0)
DI
DO
X122.8
DI/DO 9
p0728.9 (0)
DI/DO 8
X122.7
p0728.8 (0)
1
0
1
1
0
1
1
0
1
0
24 V
5 V
0
1
0
1
+24 V
X124.M
X124.+
+
M
X124.M M
24 V DC to the next device
X124.+
+24 V
<1> The connection shown as a dashed
line applies when used as digital
output (p0728.x = 1).
<1>
<1>
DI
DO
DI
DO
<2> Can be used as fast measuring probe inputs (refer to [4735], [4740]).
<3> Can only be used SIMOTION D.
1
1
r0723
CU DI status inv
r0722
CU DI status
r0723.9
r0723.8
r0721.8
r0721.9
CU S_Src DI/DO 9
p0739 (0)
CU S_Src DI/DO 8
p0738 (0)
DI/DO 8 (X122.7)
r0747.8
DI/DO 9 (X122.8)
r0747.9
DI/DO 9 (X122.8)
r0722.9
DI/DO 8 (X122.7)
r0722.8
r0747
CU DO status
<3>
DI 9_probe <2>
p0799 (4000.00 µs)

Table of Contents