List of parameters
Parameters
1-469
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: p0391, p0392 and p0393 are only available for SERVO.
Refer to: p0391, p0392, p0393
Note: For p0393 = 100 %, the current controller adaptation is disabled and p1715 is effective over the entire range.
Description: Sets the integral-action time of the current controller.
Dependency: Refer to: p1715
Description: Displays the actual output of the Isq current controller (torque/force generating current, PI controller). The value
contains the proportional and integral components of the PI controller.
Description: Displays the integral component of the Isq current controller (torque/force-generating current, PI controller).
Description: Displays the actual output of the Isd current controller (flux-generating current, PI controller). The value contains the
proportional and integral components of the PI controller.
Description: Displays the integral component of the Isd current controller (flux-generating current, PI controller).
p1717[0...n] Current controller integral-action time / I_ctrl Tn
SERVO, VECTOR
(n/M)
Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5714, 6714
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [ms] 1000.00 [ms] 2.00 [ms]
r1718 CO: Isq controller output / Isq_ctrl outp
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 6714
P-Group: Closed-loop control Units group: 5_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r1719 Isq controller integral component / Isq_ctrl I_comp
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: 5_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r1723 CO: Isd controller output / Isd_ctrl outp
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: 6714
P-Group: Closed-loop control Units group: 5_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r1724 Isd controller integral component / Isd_ctrl I_comp
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: 5_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]