Page #1303 background imageLoading...
Page #1303 background image
Vector control
Function Diagrams
2-1303
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-184 6721 – Id setpoint (PEM, p0300 = 2)
- 6721 -
Function diagram
87654321
fp_6721_01_eng.vsd
DO: VECTOR
SINAMICS S
19.04.06 V02.05.00
Vector control - Id setpoint (PEM, p0300 = 2)
M_set steady-state
p1610[D]
Mot t_excitation
p0346
1
0
r1751.0
from the model control
I_set T_smooth
p1616
r0077
Iq_set
[6060.6]
<1> Only for vector control without encoder (SLVC).
<1>
To current controller
[6714]
Refer to [1020.7]
p0115[y] (Motor Modules)
MAX
MIN
22
Iq
Iabs
Mot load angle opt
p0327[M]
From Id_field weakening
[6724]
Id_setp total
r1624
Mot kt
p0316[M]
Mot kt_reluctance
p0328[M]
Mot L_stator_d
p0378[M]
Mot L_leakage total
p0377[M]
M
Iq
[6640.5]
[6710.2]
[6714.6]
[6714]
Load angle correction
Ld
Lq
kt
rel
kt
r1762 Mot mod dev comp 1
[6731.2]
PEM: Permanent-magnet synchronous motor
[6731]
Torque setting value, speed controller
[6040]
M_suppl_accel
p1611[D]
r1515 M_suppl total
r1797 MotMod kT corr
from model control
[6731.3]
[6060.4]
r1518 M_acceleration
0.9 x r0067
r1538
r1539
r0067
n-Ctrl = 1
Open-loop
controlled
operation
&
select n-ctrl
M adaptation
Iabs
pre
M
1
0
Id_set
Iabs
(r1407.2)
0 = M-ctrl
1 = n-ctrl
I
d
Id_inject
Iq
M
MotMod w/o enc
p1757[D]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S Series and is the answer not in the manual?

Siemens SINAMICS S Series Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals