EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-184 6721 - Id setpoint (PEM, p0300 = 2)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vector control
Function Diagrams
2-1303
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-184 6721 – Id setpoint (PEM, p0300 = 2)
- 6721 -
Function diagram
87654321
fp_6721_01_eng.vsd
DO: VECTOR
SINAMICS S
19.04.06 V02.05.00
Vector control - Id setpoint (PEM, p0300 = 2)
M_set steady-state
p1610[D]
Mot t_excitation
p0346
1
0
r1751.0
from the model control
I_set T_smooth
p1616
r0077
Iq_set
[6060.6]
<1> Only for vector control without encoder (SLVC).
<1>
To current controller
[6714]
Refer to [1020.7]
p0115[y] (Motor Modules)
MAX
MIN
22
Iq
Iabs
Mot load angle opt
p0327[M]
From Id_field weakening
[6724]
Id_setp total
r1624
Mot kt
p0316[M]
Mot kt_reluctance
p0328[M]
Mot L_stator_d
p0378[M]
Mot L_leakage total
p0377[M]
M
Iq
[6640.5]
[6710.2]
[6714.6]
[6714]
Load angle correction
Ld
Lq
kt
rel
kt
r1762 Mot mod dev comp 1
[6731.2]
PEM: Permanent-magnet synchronous motor
[6731]
Torque setting value, speed controller
[6040]
M_suppl_accel
p1611[D]
r1515 M_suppl total
r1797 MotMod kT corr
from model control
[6731.3]
[6060.4]
r1518 M_acceleration
0.9 x r0067
r1538
r1539
r0067
n-Ctrl = 1
Open-loop
controlled
operation
&
select n-ctrl
M adaptation
Iabs
pre
M
1
0
Id_set
Iabs
(r1407.2)
0 = M-ctrl
1 = n-ctrl
I
d
Id_inject
Iq
M
MotMod w/o enc
p1757[D]

Table of Contents

Related product manuals