Parameters
List of parameters
1-730
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the actual value of the voltage measured at the 10 V input 1 of the Voltage Sensing Modules (VSM).
Dependency: Refer to: p3670
Note: 10 V input 1: Terminals X520.1 and X520.2
Description: Displays the actual value of the voltage measured at the 10 V input 1 of the Voltage Sensing Modules (VSM).
Dependency: Refer to: p3670
Note: 10 V input 1: Terminals X520.1 and X520.2
Description: Displays the actual value of the voltage measured at the 10 V input 2 of the Voltage Sensing Modules (VSM).
Dependency: Refer to: p3670
Note: 10 V input 2: Terminals X520.3 and X520.4
Description: Displays the actual value of the voltage measured at the 10 V input 2 of the Voltage Sensing Modules (VSM).
Dependency: Refer to: p3670
Note: 10 V input 2: Terminals X520.3 and X520.4
r3673 CO: VSM 10 V input 1 actual value / VSM inp 1 V_act
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 9880
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r3673[0...n] CO: VSM 10 V input 1 actual value / VSM inp 1 V_act
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: p0150 Func. diagram: 9880
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r3674 CO: VSM 10 V input 2 actual value / VSM inp 2 V_act
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 9880
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r3674[0...n] CO: VSM 10 V input 2 actual value / VSM inp 2 V_act
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: p0150 Func. diagram: 9880
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]