Siemens SINAMICS S Series - r1841 Actual value correction status word; AVC status; p1845[0...n] Actual value correction evaluation factor Lsig; ActV_corr FactLsig; p1846[0...n] Actual value correction damping factor; ActV_corr D_factor; r1848[0...5] Actual value correction phase currents; ActVal_corr I_corr

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-491
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p1802
Note: During operation (the pulses enabled) the configuration cannot be changed by changing-over drive data sets.
Description: Status of the actual value correction
Description: Sets the weighting factor for the leakage inductance of the L-R element of the actual value correction.
Description: Sets the damping factor for the actual value correction.
The factor multiplies the T0/Tsig ratio in the feedback branch of the LR element
Description: Displays phase correction currents as well as the drive converter phase currents
Bit field: Bit Signal name 1 signal 0 signal FP
00 Actual value correction de-activated Yes No -
01 Compares the integrals from modulator and
setpoint
Yes No -
r1841 Actual value correction status word / AVC status
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Hardware for the actual value correction
detected
Yes No -
01 Automatic shutdown (too many switching
instants)
Yes No -
02 Integral normalized to half the gating unit
clock cycle freq.
Yes No -
03 Actual value correction temporarily sup-
pressed
Yes No -
15 Actual value correction active Yes No -
p1845[0...n] Actual value correction evaluation factor Lsig / ActV_corr FactLsig
VECTOR Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 10.00 1.00
p1846[0...n] Actual value correction damping factor / ActV_corr D_factor
VECTOR Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 10.00 1.00
r1848[0...5] Actual value correction phase currents / ActVal_corr I_corr
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -