List of parameters
Parameters
1-491
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p1802
Note: During operation (the pulses enabled) the configuration cannot be changed by changing-over drive data sets.
Description: Status of the actual value correction
Description: Sets the weighting factor for the leakage inductance of the L-R element of the actual value correction.
Description: Sets the damping factor for the actual value correction.
The factor multiplies the T0/Tsig ratio in the feedback branch of the LR element
Description: Displays phase correction currents as well as the drive converter phase currents
Bit field: Bit Signal name 1 signal 0 signal FP
00 Actual value correction de-activated Yes No -
01 Compares the integrals from modulator and
setpoint
Yes No -
r1841 Actual value correction status word / AVC status
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Hardware for the actual value correction
detected
Yes No -
01 Automatic shutdown (too many switching
instants)
Yes No -
02 Integral normalized to half the gating unit
clock cycle freq.
Yes No -
03 Actual value correction temporarily sup-
pressed
Yes No -
15 Actual value correction active Yes No -
p1845[0...n] Actual value correction evaluation factor Lsig / ActV_corr FactLsig
VECTOR Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 10.00 1.00
p1846[0...n] Actual value correction damping factor / ActV_corr D_factor
VECTOR Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 10.00 1.00
r1848[0...5] Actual value correction phase currents / ActVal_corr I_corr
VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -