Parameters
List of parameters
1-446
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p3842
Notice: The signal input is after the torque limit (r1538, r1539). For vector drives, the signals that are entered are only lim-
ited by the current and power limits.
Note: The signal input is preferably used to enter the friction characteristic. The friction compensation is also effective if
the speed controller output reaches its torque limits, but the current limits have still not been reached (this only
applies to vector drives).
Description: Sets the signal source for supplementary force 3.
Dependency: Refer to: p3842
Notice: The signal input is after the force limit (r1538, r1539). For vector drives, the signals that are entered are only limited
by the current and power limits.
Note: The signal input is preferably used to enter the friction characteristic. The friction compensation is also effective if
the velocity controller output reaches its force limits, but the current limits have still not been reached (this only
applies to vector drives).
Description: Sets the flux setpoint referred to rated motor flux.
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: For p1570 > 100 %, the flux setpoint increases as a function of the load from 100 % (no-load operation) to the set-
ting in p1570 (above rated motor torque).
Description: Sets the signal source for the supplementary flux setpoint.
Notice: Low flux setpoints can cause the drive to stall at higher loads. This is the reason that the flux setpoint should only be
adapted for slow load changes.
Note: The supplementary flux setpoint is limited to +/- 50 %.
p1569[0...n] CI: Supplementary force 3 / F_suppl 3
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 7010
P-Group: Functions Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 3841[0]
p1570[0...n] CO: Flux setpoint / Flux setpoint
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6722
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
50.0 [%] 200.0 [%] 100.0 [%]
p1571[0...n] CI: Supplementary flux setpoint / Suppl flux setp
VECTOR (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6060
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- - 0