List of faults and alarms
Faults and Alarms
3-1455
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
A01323 Topology: More than two part lists set-up
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: Partial lists are available more than twice in p0978. After the second 0, all must be 0.
Alarm value (r2124, interpret decimal):
Index of p0978, under which the illegal value is located.
Remedy: Set p0009 to 1 and change p0978:
Rules:
- p0978 must include all of the drive object numbers (p0101).
- it is not permissible that a drive object number is repeated.
- by entering a 0, the drive objects with PZD are separated from those without PZD.
- only 2 partial lists are permitted. After the second 0, all values must be 0.
- dummy drive object numbers (255) are only permitted in the first partial list.
A01324 Topology: Dummy drive object number incorrectly set-up
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: In p0978, dummy drive object numbers (255) are only permitted in the first partial list.
Alarm value (r2124, interpret decimal):
Index of p0978, under which the illegal value is located.
Remedy: Set p0009 to 1 and change p0978:
Rules:
- p0978 must include all of the drive object numbers (p0101).
- it is not permissible that a drive object number is repeated.
- by entering a 0, the drive objects with PZD are separated from those without PZD.
- only 2 partial lists are permitted. After the second 0, all values must be 0.
- dummy drive object numbers (255) are only permitted in the first partial list.
A01330 Topology: Quick commissioning not possible
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: Unable to carry out a quick commissioning. The existing actual topology does not fulfill the requirements.
Alarm value (r2124, interpret hexadecimal):
The cause is in byte 1 supplementary information is included in byte 2 and the high word.
Byte 1 = 1:
For a component, illegal connections were detected.
- Byte 2 = 1: For a Motor Module, more than one motor with DRIVE-CLiQ was detected.
- Byte 2 = 2: For a motor with DRIVE-CLiQ, the DRIVE-CLiQ cable is not connected to a Motor Module.
- high word = preliminary component number of the component with illegal connection.
Byte 1 = 2:
The topology contains too many components of a particular type.
- Byte 2 = 1: There is more than one Master Control Unit.
- Byte 2 = 2: There is more than 1 infeed (8 for a parallel circuit configuration).
- Byte 2 = 3: There are more than 10 Motor Modules (8 for a parallel circuit configuration).
- Byte 2 = 4: There are more than 9 encoders.
- Byte 2 = 5: There are more than 8 Terminal Modules.
- Byte 2 = 7: Unknown component type.
- Byte 2 = 8: There are more than 6 drive slaves.
- Byte 2 = 9: Connection of a drive slave not permitted.
- Byte 2 = 10: There is no Drive Master.
- Byte 2 = 11: There is more than one motor with DRIVE-CLiQ for a parallel circuit.
- high word = not used.
Byte 1 = 3:
More than 16 components are connected at a DRIVE-CLiQ socket of the Control Unit.
- byte 2 = 0, 1, 2, 3 means e.g. detected at the DRIVE-CLiQ socket X100, X101, X102, X103.
- high word = not used.