EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-55 2451 - ZSW1 status word interconnection (p2038 = 2)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROFIdrive
Function Diagrams
2-1163
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-55 2451 – ZSW1 status word interconnection (p2038 = 2)
- 2451 -
Function diagram
87654321
fp_2451_01_eng.vsd
DO: VECTOR
SINAMICS S
17.04.07 V02.05.00
PROFIdrive - ZSW1 status word interconnection (p2038 = 2)
Signal sources for ZSW1 in Interface Mode VIK-NAMUR (p2038 = 2)
<1> Used in telegram 20.
<2> The ZSW1 is generated using the binector-connector converter (BI: p2080[0...15], inversion: p2088[0].0...p2088[0].15)
<3> The master system requests the process data.
Signal Meaning
ZSW1.0
ZSW1.1
ZSW1.2
ZSW1.3
ZSW1.4
ZSW1.5
ZSW1.6
ZSW1.8
ZSW1.9
ZSW1.11
ZSW1.12
ZSW1.13
ZSW1.14
ZSW1.15
ZSW1.7
ZSW1.10
1 = Ready to operate (DC link loaded, pulses blocked)
1 = Ready to power-up
1 = Operation enabled (drive follows n_set)
1 = Fault present
1 = No coast down active (OFF2 inactive)
1 = No fast stop active (OFF3 inactive)
1 = Power-on inhibit active
1 = Alarm present
1 = Speed setpoint - actual value deviation within tolerance t_off
1 = Control requested
1 = f or n comparison value reached/exceeded
1 = I, M, or P limit not reached
Reserved
1 = No motor overtemperature alarm
1 = Display CDS
1 = Motor rotates forwards (n_act 0)
0 = Motor rotates backwards (n_act < 0)
<3>
p2080[2] = r0899.2
p2080[3] = r2139.3
p2080[4] = r0899.4
p2080[5] = r0899.5
p2080[6] = r0899.6
p2080[7] = r2139.7
p2080[8] = r2197.7
p2080[9] = r0899.9
p2080[10] = r2199.1
p2080[11] = r0056.13
-
p2080[13] = r2135.14
p2080[0] = r0899.0
p2080[1] = r0899.1
p2080[14] = r2197.3
Interconnection
parameters
[2503.7]
[2548.7]
[2503.7]
[2503.7]
[2503.7]
[2548.7]
[2534.7]
[2503.7]
[2536.7]
[2522.7]
-
[2548.7]
-
[2503.7]
[2503.7]
[2534.7]
[Function diagram]
Internal status word
[2610]
[8060]
[2610]
[2610]
[2610]
[8065]
[8010]
[2503]
[8010]
[6060]
-
[8016]
-
[2610]
[2610]
[8010]
[Function diagram]
Signal source
<1>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
<2>
Inverted
p2080[15] = r0836.0
Refer to [1020.7]
PROFIdrive sampling time

Table of Contents

Related product manuals