Description: Sets the traversing blocks for sorting corresponding to their block number.
p2624 = 0 --> 1:
The sorting is started and the parameters are automatically reset to 0 after the sorting operation has been com-
pleted.
Dependency: Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623
Note: After sorting, the traversing blocks are written at the beginning of the memory in increasing sequence without any
gaps.
Description: Sets the signal source to select the traversing block, bit 0.
Dependency: Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2626, p2627, p2628, p2629, p2630
Description: Sets the signal source to select the traversing block, bit 1.
Dependency: Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2627, p2628, p2629, p2630
Description: Sets the signal source to select the traversing block, bit 2.
Dependency: Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2626, p2628, p2629, p2630
p2624 EPOS traversing block, sorting / Trav_block sort
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: 3616
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p2625 BI: EPOS traversing block selection, bit 0 / Trav_blk sel bit 0
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3640
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2626 BI: EPOS traversing block selection, bit 1 / Trav_blk sel bit 1
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3640
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2627 BI: EPOS traversing block selection, bit 2 / Trav_blk sel bit 2
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3640
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting