Siemens SINAMICS S Series - r1169 CO: Speed controller, speed setpoints 1 and 2; n_ctrl n_set 1;2; r1169 CO: Velocity controller, velocity setpoints 1 and 2; v_ctrl n_set 1;2; r1170 CO: Speed controller, setpoint sum; n_ctrl setp sum; r1170 CO: Velocity controller, setpoint sum; v_ctrl setp sum

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-329
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the speed setpoint after the addition of the speed setpoint 1 (p1155) and speed setpoint 2 (p1160).
Dependency: Refer to: p1155, p1160
Note: The value is only correctly displayed when the drive has been enabled.
Description: Displays the velocity setpoint after the addition of the velocity setpoint 1 (p1155) and velocity setpoint 2 (p1160).
Dependency: Refer to: p1155, p1160
Note: The value is only correctly displayed when the drive has been enabled.
Description: Displays the speed setpoint after selecting the ramp-function generator and adding the speed setpoint 1 (p1155)
and speed setpoint 2 (p1160).
Dependency: Refer to: r1150, p1155, p1160
Description: Displays the velocity setpoint after selecting the ramp-function generator and adding the velocity setpoint 1 (p1155)
and velocity setpoint 2 (p1160).
Dependency: Refer to: r1150, p1155, p1160
r1169 CO: Speed controller, speed setpoints 1 and 2 / n_ctrl n_set 1/2
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3080
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1169 CO: Velocity controller, velocity setpoints 1 and 2 / v_ctrl n_set 1/2
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3080
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
r1170 CO: Speed controller, setpoint sum / n_ctrl setp sum
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 1590,
3080, 5020
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1170 CO: Velocity controller, setpoint sum / v_ctrl setp sum
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 1590,
3080, 5020
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]