List of parameters
Parameters
1-733
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The binector output uses a 1 signal to indicate an overtemperature condition at the connected temperature sensor
of the braking resistor.
Description: The binector output uses a 1 signal to indicate that the highest permissible overtemperature at the connected tem-
perature sensor has been reached and has caused a trip (shutdown).
Dependency: Refer to: F06908
Description: The binector output uses a 1 signal to indicate that there is a Vce fault in the Digital Braking Module.
Dependency: Refer to: F06909
Description: Sets the configuration for APC (Advanced Positioning Control).
Note: Re bit 0:
For a 1 signal, the acceleration filter output is added to the speed setpoint.
For a 0 signal, the value 0 is added. This must be used to evaluate the filter frequency characteristics.
Re bit 8:
For bit 0 = 1 and activated pulse de-coupling (bit 8 = 1), the speed of the direct measuring system (p3701) selected
for APC is used as the actual value for the closed-loop speed control.
r3687 BO: Digital Braking Module pre-alarm overtemperature / Dig BM temp alarm
B_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r3688 BO: Digital Braking Module fault overtemperature / Dig BM temp fault
B_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r3689 BO: Digital Braking Module Vce fault / Dig BM Uce fault
B_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p3700 APC configuration / APC config
SERVO (APC) Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: 7012
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Activating APC Yes No -
08 Activating pulse de-coupling Yes No -