Siemens SINAMICS S Series - r3687 BO: Digital Braking Module pre-alarm overtemperature; Dig BM temp alarm; r3688 BO: Digital Braking Module fault overtemperature; Dig BM temp fault; r3689 BO: Digital Braking Module Vce fault; Dig BM Uce fault; p3700 APC configuration; APC config

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-733
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The binector output uses a 1 signal to indicate an overtemperature condition at the connected temperature sensor
of the braking resistor.
Description: The binector output uses a 1 signal to indicate that the highest permissible overtemperature at the connected tem-
perature sensor has been reached and has caused a trip (shutdown).
Dependency: Refer to: F06908
Description: The binector output uses a 1 signal to indicate that there is a Vce fault in the Digital Braking Module.
Dependency: Refer to: F06909
Description: Sets the configuration for APC (Advanced Positioning Control).
Note: Re bit 0:
For a 1 signal, the acceleration filter output is added to the speed setpoint.
For a 0 signal, the value 0 is added. This must be used to evaluate the filter frequency characteristics.
Re bit 8:
For bit 0 = 1 and activated pulse de-coupling (bit 8 = 1), the speed of the direct measuring system (p3701) selected
for APC is used as the actual value for the closed-loop speed control.
r3687 BO: Digital Braking Module pre-alarm overtemperature / Dig BM temp alarm
B_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r3688 BO: Digital Braking Module fault overtemperature / Dig BM temp fault
B_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r3689 BO: Digital Braking Module Vce fault / Dig BM Uce fault
B_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p3700 APC configuration / APC config
SERVO (APC) Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: 7012
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Activating APC Yes No -
08 Activating pulse de-coupling Yes No -