EasyManua.ls Logo

Siemens SINAMICS S Series - p8732[0...3] CBC send mapping for TPDO 3; Mapping TPDO 3; p8733[0...3] CBC send mapping for TPDO 4; Mapping TPDO 4; p8734[0...3] CBC send mapping for TPDO 5; Mapping TPDO 5; p8735[0...3] CBC send mapping for TPDO 6; Mapping TPDO 6

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-949
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the mapping parameters for CANopen Transmit Process Data Object 3 (TPDO 3).
Index: [0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note: Corresponds to the CANopen object 1A02 hex + 40 hex * x (x: Drive number 0 ... 7).
Description: Sets the mapping parameters for CANopen Transmit Process Data Object 4 (TPDO 4).
Index: [0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note: Corresponds to the CANopen object 1A03 hex + 40 hex * x (x: Drive number 0 ... 7).
Description: Sets the mapping parameters for CANopen Transmit Process Data Object 5 (TPDO 5).
Index: [0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note: Corresponds to the CANopen object 1A04 hex + 40 hex * x (x: Drive number 0 ... 7).
Description: Sets the mapping parameters for CANopen Transmit Process Data Object 6 (TPDO 6).
p8732[0...3] CBC send mapping for TPDO 3 / Mapping TPDO 3
SERVO (CAN), VEC-
TOR (CAN)
Can be changed: C1(3), T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 9208, 9210
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p8733[0...3] CBC send mapping for TPDO 4 / Mapping TPDO 4
SERVO (CAN), VEC-
TOR (CAN)
Can be changed: C1(3), T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 9208, 9210
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p8734[0...3] CBC send mapping for TPDO 5 / Mapping TPDO 5
SERVO (CAN), VEC-
TOR (CAN)
Can be changed: C1(3), T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 9208
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p8735[0...3] CBC send mapping for TPDO 6 / Mapping TPDO 6
SERVO (CAN), VEC-
TOR (CAN)
Can be changed: C1(3), T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 9208
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex

Table of Contents

Related product manuals