List of parameters
Parameters
1-205
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
If a parameter change is rejected, it should be checked as to whether the input terminal is already being used in
p0488, p0489, p0495, p0680, p2517 or p2518.
Description: Sets the edge to evaluate the measuring probe signal for speed actual value measurement.
0: 0/1 edge
1: 1/0 edge
Dependency: Refer to: p0580
Description: Sets the number of pulses per revolution (e.g. for disks with holes).
Description: Sets the maximum measuring time for the measuring probe.
If a new pulse is not received before the maximum measuring time has expired, then the speed actual value in
r0586 is set to zero. This timer stage is re-started with the next pulse.
Dependency: Refer to: r0586
Description: Displays the speed actual value measured using the BERO.
Dependency: Refer to: p0580, p0583
Note: For p0580 = 0 (no measuring probe), a value of zero is displayed here.
p0581 Meas probe, edge / MT edge
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p0582 Measuring probe, pulses per revolution / MT pulses per rev
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 12 1
p0583 Measuring probe, maximum measuring time / MT t_meas max
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.040 [s] 10.000 [s] 10.000 [s]
r0586 CO: Measuring probe, speed actual value / MT n_act
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]