EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-199 7016 - Internal armature short-circuit (IVP, p0300 = 2 xx or 4 xx)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technology functions
Function Diagrams
2-1319
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-199 7016 – Internal armature short-circuit (IVP, p0300 = 2xx or 4xx)
- 7016 -
Function diagram
87654321
fp_7016_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
22.05.07 V02.05.01
Technology functions - Internal Armature Short-Circuit (IASC, p0300 = 2xx or 4xx)
2000 µs
DRIVE-CLiQ
Control Unit Motor Module
~
M
3
Drive converter
F07907
"Motor terminals are not at zero potential after pulse cancellation"
p1231 = 4
Fault response, Internal Armature Short-Circuit
(1)
ASC act
p1230
Armature short-circuit, enable missing
r0046.4
Control of armature short-circuiting in the power unit
Armature short-circuit, internal enable missing
r0046.20
IASC: Internal Armature Short-Circuit