Figure 2-199 7016 – Internal armature short-circuit (IVP, p0300 = 2xx or 4xx)
- 7016 -
Function diagram
87654321
fp_7016_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
22.05.07 V02.05.01
Technology functions - Internal Armature Short-Circuit (IASC, p0300 = 2xx or 4xx)
2000 µs
DRIVE-CLiQ
Control Unit Motor Module
~
M
3
Drive converter
F07907
"Motor terminals are not at zero potential after pulse cancellation"
p1231 = 4
Fault response, Internal Armature Short-Circuit
(1)
ASC act
p1230
Armature short-circuit, enable missing
r0046.4
Control of armature short-circuiting in the power unit
Armature short-circuit, internal enable missing
r0046.20
IASC: Internal Armature Short-Circuit