EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-31 2120 - Digital inputs, electrically isolated (DI 0... DI 3)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CU320 input/output terminals
Function Diagrams
2-1135
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-31 2120 – Digital inputs, electrically isolated (DI 0 ... DI 3)
- 2120 -
Function diagram
87654321
fp_2120_51_eng.vsd
DO: CU_GL, CU_GM, CU_S
SINAMICS
19.05.06 V02.05.00
CU320 input/output terminals - Digital inputs, electrically isolated (DI 0 ... DI 3)
+24 V
X124.M
X124.+
+
X122.1
X122.2
X122.3
X122.4
1 = Simulation on
p0795.0
r0723.0
r0722.0
p0795.1
r0723.1
r0722.1
p0795.2
r0723.2
r0722.2
p0795.3
r0723.3
r0722.3
r0722r0723
X122.5
M1
M
M
X124.M
M
+
24 V
5 V
<1>
When using the electrical isolation, omit the
terminal jumper and connect the load power
supply shown as a dashed line.
<1>
X122.6
24 V DC to the next device
X124.+
+24 V
1
0
1
0
1
0
1
0
1
1
1
1
24 V
DI 3
DI 2
DI 1
DI 0
<1>
DI 0...DI 15
inverted
DI 0...DI 15
r0721.0
r0721.1
r0721.2
r0721.3
<1>
p0796.3
p0796.2
p0796.1
p0796.0
<1>
p0799

Table of Contents