EasyManua.ls Logo

Siemens SINAMICS S Series - r9481 Number of BICO interconnections; BICO count; r9482[0...59] BICO interconnections BI;CI parameters; BICO BI;CI par; r9483[0...59] BICO interconnections BO;CO parameters; BICO BO;CO par

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-989
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the number of BICO interconnections (signal drains) to other drive objects.
The selected BICO interconnections should be entered into r9482[0...59] and r9483[0...59].
Dependency: Refer to: r9482, r9483
Description: Displays the signal drains (Binector/Connector Inputs, BI/CI parameters) to other drive objects.
The number of BICO interconnections to other drive objects is displayed in r9481.
Dependency: Refer to: r9481, r9483
Note: The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal drain, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal drain, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
Description: Displays the signal sources (Binector/Connector Outputs, BO/CO parameters) to other drive objects.
The number of BICO interconnections to other drive objects is displayed in r9481.
Dependency: Refer to: r9481, r9482
Note: The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal drain, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal drain, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
r9481 Number of BICO interconnections / BICO count
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, SERVO,
S_INF, TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41,
TM54F_MA,
TM54F_SL, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
r9482[0...59] BICO interconnections BI/CI parameters / BICO BI/CI par
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, SERVO,
S_INF, TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41,
TM54F_MA,
TM54F_SL, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
r9483[0...59] BICO interconnections BO/CO parameters / BICO BO/CO par
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, SERVO,
S_INF, TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41,
TM54F_MA,
TM54F_SL, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -

Table of Contents