List of parameters
Parameters
1-989
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the number of BICO interconnections (signal drains) to other drive objects.
The selected BICO interconnections should be entered into r9482[0...59] and r9483[0...59].
Dependency: Refer to: r9482, r9483
Description: Displays the signal drains (Binector/Connector Inputs, BI/CI parameters) to other drive objects.
The number of BICO interconnections to other drive objects is displayed in r9481.
Dependency: Refer to: r9481, r9483
Note: The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal drain, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal drain, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
Description: Displays the signal sources (Binector/Connector Outputs, BO/CO parameters) to other drive objects.
The number of BICO interconnections to other drive objects is displayed in r9481.
Dependency: Refer to: r9481, r9482
Note: The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal drain, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal drain, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
r9481 Number of BICO interconnections / BICO count
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, SERVO,
S_INF, TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41,
TM54F_MA,
TM54F_SL, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
r9482[0...59] BICO interconnections BI/CI parameters / BICO BI/CI par
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, SERVO,
S_INF, TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41,
TM54F_MA,
TM54F_SL, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
r9483[0...59] BICO interconnections BO/CO parameters / BICO BO/CO par
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, SERVO,
S_INF, TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41,
TM54F_MA,
TM54F_SL, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -