EasyManua.ls Logo

Siemens SINAMICS S Series - p10024[0...3] SI SS2 input terminal; SI SS2 DI; p10025[0...3] SI SOS input terminal; SI SOS DI

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-1054
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
255: Statically inact
Index: [0] = Drive group 1
[1] = Drive group 2
[2] = Drive group 3
[3] = Drive group 4
Note: SS1: Safe Stop 1
Re value = 0:
No terminal assigned, safety function always active.
Re value = 255:
No terminal assigned, safety function always inactive.
Description: Assignment of the input terminals for input SS2 (operating mode = control interface)
Description, refer to P10022
Values: 0: Statically active
1: F-DI 0 (X521.2/3/6)
2: F-DI 1 (X521.4/5/7)
3: F-DI 2 (X522.1/2/7)
4: F-DI 3 (X522.3/4/8)
5: F-DI 4 (X522.5/6/9)
6: F-DI 5 (X531.2/3/6)
7: F-DI 6 (X531.4/5/7)
8: F-DI 7 (X532.1/2/7)
9: F-DI 8 (X532.3/4/8)
10: F-DI 9 (X532.5/6/9)
255: Statically inact
Index: [0] = Drive group 1
[1] = Drive group 2
[2] = Drive group 3
[3] = Drive group 4
Note: SS2: Safe Stop 2
Re value = 0:
No terminal assigned, safety function always active.
Re value = 255:
No terminal assigned, safety function always inactive.
Description: Assignment of the input terminals for input SOS (operating mode = control interface)
Description, refer to P10022
Values: 0: Statically active
1: F-DI 0 (X521.2/3/6)
2: F-DI 1 (X521.4/5/7)
3: F-DI 2 (X522.1/2/7)
4: F-DI 3 (X522.3/4/8)
p10024[0...3] SI SS2 input terminal / SI SS2 DI
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 255 0
p10025[0...3] SI SOS input terminal / SI SOS DI
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 255 0