List of parameters
Parameters
1-245
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
2. The status bit p0830.5 is set. If the feedback signal (p0831[5]) is connected, the system waits until the feedback
signal "contactor closed" is displayed. If the feedback signal is not connected, then the system waits for the switch-
on interlocking time of 160 ms.
Index: [0] = Feedback signal contactor 0
[1] = Feedback signal contactor 1
[2] = Feedback signal contactor 2
[3] = Feedback signal contactor 3
[4] = Feedback signal contactor 4
[5] = Feedback signal contactor 5
[6] = Feedback signal contactor 6
[7] = Feedback signal contactor 7
[8] = Feedback signal contactor 8
[9] = Feedback signal contactor 9
[10] = Feedback signal contactor 10
[11] = Feedback signal contactor 11
[12] = Feedback signal contactor 12
[13] = Feedback signal contactor 13
[14] = Feedback signal contactor 14
[15] = Feedback signal contactor 15
Description: Displays the status word of the contactor feedback signals when changing over a motor.
Dependency: Refer to: p0831
Description: Sets the configuration for the motor and encoder changeover.
r0832.0...15 CO/BO: Mot. changeover, contactor feedback sig. status word / Mot_chng fdbk ZSW
SERVO, VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: 8575
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Feedback signal contactor 0 Closed Opened -
01 Feedback signal contactor 1 Closed Opened -
02 Feedback signal contactor 2 Closed Opened -
03 Feedback signal contactor 3 Closed Opened -
04 Feedback signal contactor 4 Closed Opened -
05 Feedback signal contactor 5 Closed Opened -
06 Feedback signal contactor 6 Closed Opened -
07 Feedback signal contactor 7 Closed Opened -
08 Feedback signal contactor 8 Closed Opened -
09 Feedback signal contactor 9 Closed Opened -
10 Feedback signal contactor 10 Closed Opened -
11 Feedback signal contactor 11 Closed Opened -
12 Feedback signal contactor 12 Closed Opened -
13 Feedback signal contactor 13 Closed Opened -
14 Feedback signal contactor 14 Closed Opened -
15 Feedback signal contactor 15 Closed Opened -
p0833 Data set changeover configuration / DS_chng config
SERVO Can be changed: C2(15), U Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: 8575
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin